IMRT / VMAT / IGRT

The comprehensive set of solutions for pre- and intra-treatment dose verification that encompasses all current radiotherapy techniques: VMAT, IMRT, SBRT, 4D-RT, and Tomotherapy. It enables quality control that ensures that the dose administered to the patient effectively corresponds to the planned dose.

Delta4 Phantom+

Wireless equipment ensures accurate and efficient verification of IMRT, VMAT, and Tomotherapy plans. This is the only system on the market that effectively measures dose distribution in the isocentric region, including:

  • Battery-powered and wireless operation.
  • State-of-the-art detectors, with no need for recalibration.
  • Option for absolute dose measurement by ionization chamber.

The Delta4 Phantom+ is also available in Plastic Water® (registered trademark of CIRS Inc), compatible with TG-51 and TRS-398 protocols

Hexamotion

Delta4 HexaMotion is a motion platform that recreates tumor movement in six dimensions, enabling dose verification in moving targets.

This platform also allows you to assess which patients truly benefit from motion control.

Adaptivo

Quality control of IMRT and VMAT treatments based on information collected by EPID – no need to use phantoms. This software provides a true picture of the patient and the dose administered at each stage of treatment, improving the ability to adapt treatment plans when necessary.

Adaptivo not only automates the verification of pre-treatment and administered doses, but also uses daily CBCT to automatically compare daily and cumulative doses with the planned dose in 3D.

The software automatically imports and analyzes patient information, displays the information schematically on a control panel, and issues alerts for dose deviations that require intervention/change.

A clinically relevant tool that provides information for quick use and significantly improves the quality of treatments!

IMSure QA Software

Used for independent and accurate verification of monitor units (MU), dose, and overall validation

of 3D-CRT and IMRT/VMAT plans—no films, phantoms, or accelerator time required.

 

  • Unprecedented accuracy through the patented “3-Source Model” algorithm – Includes, in the dose calculation, the contribution of scatter caused by the flattening filter and the primary collimator.
  • Easy and intuitive verification of MU and comparative QC of IMRT plans.
  • Module for verification of Cyberknife plans.
  • The Brachytherapy plan verification module allows independent validation of HDR (High Dose Rate) and LDR (Low Dose Rate) plans by analyzing the contributions and positions of each source. Ensures dose calculation compliance and discrepancy detection—all without the need for phantoms or other equipment.

 

Non-IMRT plans for photons and electrons are easily verified, displaying the results on a single screen.

 

  1. Supports open fields, blocks, stereotactic cones, and wedged fields including Varian Enhanced Dynamic Wedge and Elekta Omni Wedge.
  2. Support for In-vivo measurements – Automatically calculates a given reading for a diode placed on the surface relative to the isocenter or other valid calculation point.
  3. Multiple calculation points – Allows evaluation of an unlimited number of points of interest.. Decimal Compensator Support – Uses a convolution algorithm to model scatter, beam hardening effects, and field size dependencies to calculate a realistic compensator factor even for the most complex sub-decimal filters.

LinacView

Log file analysis for all patients. Automatic verification of equipment performance for each fraction, without impacting workflow. Quickly identify and resolve the cause of irradiation problems that may interfere with treatment quality.

Automatically compares log files with the treatment plan during the patient’s treatment. The software continuously acquires new information and sends automatic alerts to verify the results. Values that are outside tolerance instantly generate an alert email for immediate action.

 

Collection of all treatment details.

Deviations between planned positions and measured positions during treatment are analyzed and summarized for each patient plan, indicating the possible causes for the detected error. It allows you to measure the temporal displacement of the blade positions and the percentage of Monitor Units administered, as well as to make comparisons regarding gantry angulation and the gamma index of the fluence map (planning VS treatment).

 

Complete analysis of the treatment plan and equipment performance.

LinacView allows you to check not only the performance of the equipment during treatments but also to perform pre-treatment QC. It also allows you to predict when new maintenance will be required, preventing equipment performance from jeopardizing normal clinical operation.

All results are stored in the database and can be accessed at any time, allowing you to create reports on a specific treatment or on equipment performance over time.

RayFilm

Complete 3D analysis of patient-specific IMRT, VMAT, RapidArc, CyberKnife and SRS QA. For thousands less, RayTM (Radiation Analyzer) includes advanced features not found in other film dosimetry software.