Pre-Treatment QA
Evaluate each IMRT, VMAT, Tomotherapy, or SRS plan before treating the patient: from the wireless Delta⁴ Phantom+ to the HexaMotion platform for moving targets, through IMSure and RayFilm for independent dose verification. Fast, accurate answers that confirm monitor units, dose distribution, and motion effect, ensuring that the radiation beam matches the calculated plan — without taking up accelerator time or adding clinical complexity.
Delta4 Phantom+
Wireless equipment ensures accurate and efficient verification of IMRT, VMAT, and Tomotherapy plans. This is the only system on the market that effectively measures dose distribution in the isocentric region, including:
- Battery-powered and wireless operation.
- State-of-the-art detectors, with no need for recalibration.
- Option for absolute dose measurement by ionization chamber.
The Delta4 Phantom+ is also available in Plastic Water® (registered trademark of CIRS Inc), compatible with TG-51 and TRS-398 protocols.
Hexamotion
Delta4 HexaMotion is a motion platform that recreates tumor movement in six dimensions, enabling dose verification in moving targets. This platform also allows you to assess which patients truly benefit from motion control.
IMSure QA Software
Used for independent and accurate verification of monitor units (MU), dose, and overall validation
of 3D-CRT and IMRT/VMAT plans—no films, phantoms, or accelerator time required.
- Unprecedented accuracy through the patented “3-Source Model” algorithm – Includes, in the dose calculation, the contribution of scatter caused by the flattening filter and the primary collimator.
- Easy and intuitive verification of MU and comparative QC of IMRT plans.
- Module for verification of Cyberknife plans.
- The Brachytherapy plan verification module allows independent validation of HDR (High Dose Rate) and LDR (Low Dose Rate) plans by analyzing the contributions and positions of each source. Ensures dose calculation compliance and discrepancy detection—all without the need for phantoms or other equipment.
Non-IMRT plans for photons and electrons are easily verified, displaying the results on a single screen.
- Supports open fields, blocks, stereotactic cones, and wedged fields including Varian Enhanced Dynamic Wedge and Elekta Omni Wedge.
- Support for In-vivo measurements – Automatically calculates a given reading for a diode placed on the surface relative to the isocenter or other valid calculation point.
- Multiple calculation points – Allows evaluation of an unlimited number of points of interest.
- Decimal Compensator Support – Uses a convolution algorithm to model scatter, beam hardening effects, and field size dependencies to calculate a realistic compensator factor even for the most complex sub-decimal filters.
RayFilm
Complete 3D analysis of patient-specific IMRT, VMAT, RapidArc, CyberKnife and SRS QA. For thousands less, RayTM (Radiation Analyzer) includes advanced features not found in other film dosimetry software.