Stereotactic

AABGT provides a complete set of solutions to ensure the accuracy and reliability of stereotactic treatments (SRS/SRT). From the LUCY 3D phantom, widely recognized for its high precision, to PIPSpro software for Winston-Lutz analysis, Exradin diodes, and the SuperMAX electrometer, each tool has been designed to meet the clinical requirements for quality control in this type of treatment. Count on us to find the configuration that best suits your system and your team’s needs.

LUCY 3D QA Phantom

It is the most widely used phantom in the world, exceeding the requirements of physicists responsible for quality control of SRS and SRT treatments. Each component is manufactured with a tolerance of 0.1 mm, ensuring the most accurate SRS treatment verification equipment.

Simple, fast, and customizable setup.

Lucy is compatible with most existing SRS frames and frameless systems, ensuring quick setup and accurate positioning tests under treatment conditions. The SRS frame (with Lucy) is placed on the treatment table and irradiated according to the manufacturer’s coordinate system.

SuperMAX Electrometer

The SuperMAX combines highly accurate, reference grade measurements, with a revolutionary touchscreen interface and a host of advanced measurement features. Support TG-51 and TRS-398 dosimetry protocols, while quickly acquiring multiple point dose measurements without re-zeroing.

  • Two Independent Measurement Channels
  • Built-In Detector Library
  • Easy-to-Use Interface
  • Store Data Collection
  • Exradin W1 Scintillator Integration

PIPSpro Software Stereotactic

The Stereotactic Module of PIPSpro Software automates the Winston-Lutz test to the highest level of accuracy in all three dimensions, providing the data necessary to correct the isocentricity of the equipment.

Exradin D1H & D1V Diode Detectors

Maximize signal and spatial resolution and minimize angular dependence for consistent, accurate small-field stereotactic measurements.

The D1V’s diode face is perpendicular to the beam when upright, making it ideal for photon scanning applications and use in water phantoms and the Lucy 3D QA Phantom.

The D1H’s diode face is perpendicular to the beam when flat, for use inside traditional solid phantoms.

Both diodes provide superior measurement of field sizes up to 20 x 20 cm2 with excellent spatial resolution and minimal noise.

Stereotactic Dose Verification Phantom - SDVP

Originally developed for Cyberknife dose measurements and quality control, this phantom also represents an excellent cost-quality alternative for dose measurements for planning system acceptance and dose verification of specific plans. It allows the use of film or ionization chambers.

With the addition of the SRS Dosimetric QA Insert, it is possible to test and evaluate image quality, treatment plan, and dose conformity for stereotactic treatments.

Adaptivo

Quality control of IMRT and VMAT treatments based on information collected by EPID – no need to use phantoms. This software provides a true picture of the patient and the dose administered at each stage of treatment, improving the ability to adapt treatment plans when necessary.

Adaptivo not only automates the verification of pre-treatment and administered doses, but also uses daily CBCT to automatically compare daily and cumulative doses with the planned dose in 3D.

The software automatically imports and analyzes patient information, displays the information schematically on a control panel, and issues alerts for dose deviations that require intervention/change.

A clinically relevant tool that provides information for quick use and significantly improves the quality of treatments!

RayFilm

Complete 3D analysis of patient-specific IMRT, VMAT, RapidArc, CyberKnife and SRS QA. For thousands less, RayTM (Radiation Analyzer) includes advanced features not found in other film dosimetry software.